| Vortex PhD™ In-Line Vortex Flow Meter | |||||||
|
|||||||
| EMCO's model Vortex PhD® is an in-line vortex shedding flow meter capable of measuring liquids or gases, including steam, for pipe sizes from 1" to 12", available in stainless steel and carbon steel. The PhD flow meter has no moving parts, rugged construction, and microprocessor-based electronics for high accuracy in many flow metering applications. The Vortex PhD flow meter, with no moving parts, provides accurate measurement with lower maintenance, and lower total cost of ownership than other flow meter technologies. |
|
||||||
| Features | |||||||
|
|||||||
| Performance Specifications | ||
| Accuracy (linear ranges) |
Liquid | ± 0.7% of flow rate |
| Gas/Steam | ± 1.0% of flow rate | |
| Repeatability | ± 0.15% of flow rate | |
| Response time | Adjustable from 1 to 100 sec (analog output version) | |
| Operating Specifications | |||
| Fluid types | Liquid, gas, or steam | ||
| Measurable flow velocities | Liquid | 1.5 to 32 ft/sec (0.5 to 9 m/s) | |
| Gas/Steam | to 300 ft/sec ( to 91 m/s) (p=density lb/ft³ (kg/m³) |
||
| Process pressure | According to flange specifications, up to ANSI class 600 | ||
| Process temperature limit | – 40 to 750°F (– 40 to 400°C) | ||
| Ambient temperature limit | Standard | – 20 to 140°F (– 29 to 60°C) | |
| With Local Display | 32 to 140 °F (0 to 60 °C) | ||
| Ambient humidity limit | Up to 100% RH non-condensing | ||
| Power requirements | Standard | 18 to 40 VDC | |
| Option | 110/220 VAC, 50/60 Hz | ||
| Output signals | Scalable 4 to 20 mA current and scalable frequency/pulse 0 to10 kHz HART® communications protocol | ||
| Physical Specifications | |||
| Materials | Wetted parts | Stainless steel, or carbon steel | |
| All other Parts | Stainless steel | ||
| Electronics enclosure | Coated 383 AL (corrosion-resistant epoxy paint) NEMA 4X | ||
| Process connection | ANSI B16.5 class 150, 300, or 600 DIN 2501, PN16, PN40, PN64 | ||
| Transmitter | Standard | Single transmitter, single sensor | |
| Mounting | Standard | Transmitter integrally mounted on sensor | |
| Option | Transmitter remote mounted | ||
| Display | Standard | No display | |
| Option | Local indicator alternately displays flow rate and totalized flow in user-selectable, engineering units. It is a 2-line, 8-character per line, LCD display. | ||
| Approvals | FM | Explosion proof for Class I, Division 1, Groups B, C, & D Class II, Division 1, Groups E, F, & G Class I, Division 2, Groups A, B, C, & D Class II, III, Division 2, Groups F & G | |
| CSA | Explosion proof for Class I, Division 1, Groups B, C, & D Class II, Division 1, Groups E, F, & G Class III | ||
![]() |
Certified by DEMKO for use in potentially explosive atmosphere Eex d [ib] IIC T6 (flame proof enclosure and intrinsic safety). | ||
| Installation Specifications | |||
| Mounting | Install flow meter vertically, horizontally, or at any angle. For liquid service, the flow line must be full during flow meter operation; in vertical lines, flow direction should be upward for optimum flow meter performance. | ||
| Straight run piping | (D = internal diameter of pipe) | Upstream | Downstream |
| One 90° elbow before meter | 10 D | 5 D | |
| Two 90° elbows before meter | 15 D | 5 D | |
| Two 90° elbows out of plane before the meter |
30 D
|
5 D
|
|
| Reduction before the meter | 10 D | 5 D | |
| Regulator or valve partially closed before the meter |
30 D
|
5 D
|
|
| Pressure and temperature taps | Mount pressure tap 3.5 to 7 pipe diameters downstream of the flow meter. Mount temperature tap an additional 3.5 to 7 pipe diameters downstream of the pressure tap. | ||
| Site selection | Select installation location to minimize turbulence and swirl. The piping configuration, i.e., valves, elbows, pumps, may add disturbances to the flow. | ||
| Serviceability | The sensor element can be removed, and replaced, without removing the flow meter body from the process line and without process shutdown for process pressures below 750 psig (52 barg). | ||
| Model Codes | ||||||||
| Category | Description | Suffix Codes | ||||||
| Wetted parts | Wetted parts stainless steel (sizes 1 to 12") | PhD-90 | - | - | - | - | - | - |
| Carbon steel (sizes 6 to 12") | PhD-92 | - | - | - | - | - | - | |
| Fluid type | Steam or gas | - | S | - | - | - | - | - |
| Liquid | - | L | - | - | - | - | - | |
| Line size | 1" | - | - | 10 | - | - | - | - |
| 1.5" | - | - | 15 | - | - | - | - | |
| 2" | - | - | 20 | - | - | - | - | |
| 3" | - | - | 30 | - | - | - | - | |
| 4" | - | - | 40 | - | - | - | - | |
| 6" | - | - | 60 | - | - | - | - | |
| 8" | - | - | 80 | - | - | - | - | |
| 10" | - | - | 100 | - | - | - | - | |
| 12" | - | - | 120 | - | - | - | - | |
| 25 mm | - | - | DN25 | - | - | - | - | |
| 40 mm | - | - | DN40 | - | - | - | - | |
| 50 mm | - | - | DN50 | - | - | - | - | |
| 80 mm | - | - | DN80 | - | - | - | - | |
| 100 mm | - | - | DN100 | - | - | - | - | |
| 150 mm | - | - | DN150 | - | - | - | - | |
| 200 mm | - | - | DN200 | - | - | - | - | |
| 250 mm | - | - | DN250 | - | - | - | - | |
| 300 mm | - | - | DN300 | - | - | - | - | |
| Connection type | Wafer1 | - | - | - | W | - | - | - |
| Flange | - | - | - | F | - | - | - | |
| Connection rating | ANSI Class 150 | - | - | - | - | 150 | - | - |
| ANSI Class 300 | - | - | - | - | 300 | - | - | |
| ANSI Class 600 | - | - | - | - | 600 | - | - | |
| DIN, PN 16 | - | - | - | - | PN16 | - | - | |
| DIN, PN 40 | - | - | - | - | PN40 | - | - | |
| DIN, PN 64 | - | - | - | - | PN64 | - | - | |
| Options | No indicator/totalizer option2 | - | - | - | - | - | STD | - |
| FM Approved3 | - | - | - | - | - | FM | - | |
| CSA Approved | - | - | - | - | - | CSA | - | |
| CENELEC Approved3 | - | - | - | - | - | CEN | - | |
| Local indicator & totalizer4 | - | - | - | - | - | LOC- TOT |
- | |
| Remote Mount Electronics5 | - | - | - | - | - | RMT | - | |
| Integral 110 VAC Input6 | - | - | - | - | - | 110 | - | |
| Integral 220 VAC Input6 | - | - | - | - | - | 220 | - | |
| Internal sensor wires | Teflon, -40° to 400° F (-40° to 204° C) | - | - | - | - | - | - | T |
| Fiberglass, 150° to 750° F (65° to 400° C) | - | - | - | - | - | - | F | |
|
PhD-90-S-60-F-300-LOC-TOT-RMT-T represents a 6" in-line vortex flow meter with stainless steel wetted parts, for steam or gas applications, with ANSI class 300 flanged connection, a local indicator and totalizer, with remote-mounted transmitter, and teflon sensor wires. Notes:
|