Global Engineered Products Global Engineered Products, LLC

Consulting for industrial & municipal engineering applications · (907) 677-3770

MAGFLO Electromagnetic Flow Meters

MAGFLO® Electromagnetic
»Features »Specifications »Installation »Model Codes
 
    
»Documentation
Magflow 3100
»Technology

MAGFLO® electromagnetic flow meters offer important advantages such as, no pressure drop, no moving parts, high accuracy, and a wide variety of materials of construction. They have been successfully used in many industries, including food, beverage, chemical, paper & pulp, steel and water treatment. No maintenance, low cost of ownership and high reliability make MAGFLO® the flow meter of choice for many applications.

The SENSORPROM™ located in the terminal box of the signal converter is the  concept of the future.

  • Installation without calibration—turn on the power and the flowmeter measures flow immediately
  • The memory unit calibrates and programs the MAGFLO® flow meter automatically
  • Replacing the converter is as easy as changing a light bulb—no rewiring or programming is required

Features



Magflo 5000

Applications

  • Conductive liquids
  • Specialized version available for sanitary food applications

Easy to use

  • Backlit alphanumeric display
  • Electronic unit and display can be rotated for easy viewing

High accuracy and repeatability

  • ±0.5% of rate accuracy (MAG 5000 signal converter)
  • Optional ±0.25% of rate accuracy available (MAG 6000 signal converter)
  • Bidirectional flow measurement

Rugged construction

  • No moving parts to wear down or clog

Easy maintenance

  • SENSORPROM™ technology provides automatic download of start-up settings
  • Self diagnostics

Back to top

Specifications


Specification information can be found in the Model MAGFLO General Specification document.

Performance Specifications
Accuracy
(linear ranges)
MAG 5000 signal converter ± 0.5% of rate
MAG 6000 signal converter ± 0.25% of rate

Operating Specifications
Fluid types Liquids with an electric conductivity of > 5 µs/cm
Measurable flow velocities Adjustable from 0 to 0.8 ft/sec to 0 to 33 ft/sec
Process pressure Up to 580 psi (refer to general specifications)
Process temperature limit Up to 390°F (refer to general specifications)
Ambient temperature limit Remote signal converter -40 to 210°F (-40 to 99°C)
Integral signal converter 5 to 120°F (-15 to 49°C)